Javad Royaei, Kabir Sadeghi, Fatemeh Nouban
A comparative experimental investigation of high-temperature effect on fibre concrete and high strength concrete using UT and CM methods
Číslo: 3/2023
Periodikum: Acta Polytechnica
DOI: 10.14311/AP.2023.63.0208
Klíčová slova: fibre concrete, high strength concrete, temperature, ultrasonic text
Pro získání musíte mít účet v Citace PRO.
Based on the results of the average decrease in compressive strength versus the heat exposure time, it is observed that the trend of changes and decrease in resistance over time for both types of tests is almost the same and has a negligible difference. At the end of 180 minutes of exposure, the resistance ratio for the ultrasonic test is 69.8 %, and 71.1 % for the compression machine. Furthermore, according to the average reduction in compressive strength due to heat exposure time, it has been observed that the results of the UT and UM tests have slight numerical differences, however, the trend of changes and reduction in resistance over time for both types of tests is almost the same. Finally, the accuracy of the UT in determining the compressive strength of specimens at high temperatures is fully confirmed.